Wedding Suit & Gown
6 Ton 20 Kw 8 Hp Water Cooled Process Cooling System Refrigeration Scroll Water Chiller
2017-09-16 03:01  Visit:243
Price:Unfilled
Send inquiry

6 Ton 20 Kw 8 Hp Water Cooled Process Cooling System Refrigeration Scroll Water Chiller

We supply 6ton 20kw 8hp water cooled process cooling system refrigeration scroll water chiller. With low noise and large flow range, high efficiency, firmly and durable, we are confident to become your business partner.

6Ton Water Cooled Process Cooling System Refrigeration Scroll Water Chiller


1.Introduction of 6ton water cooled process cooling system refrigeration scroll water chiller

This 6ton water cooled process cooling system refrigeration scroll water chiller is high in reliability, which provide a steady thermal environment for chilling process and consume less power,fabricated from quality material,


2.Working principle diagram of 6ton water cooled process cooling system refrigeration scroll water chiller


3.Specification of 6ton water cooled process cooling system refrigeration scroll water chiller

Name

Water Cooled Processing Water Chiller

Model

AYD-08W

Cooling Capacity (ton/h)

6

Cold Water Flow(m3/h)

4.27

Cooling Tower Water Flow( m3/h)

5.34

Refrigerant

R22/R407C/R134A

Temp Control Scope(℃)

7-35

Compressor Input Power(KW)

6

Pump Power(KW)

0.75

Tank Volume(L)

100

The water pipe size (G")

1"

Power Supply

3N/380V/50HZ

Dimension(L×W×H)mm

1370*690*1310

Weight(KG)

210

Disposition:
1.Compressor:Sanyo;
2.Punp brand electronic board of micro computer
3.LG Exchange the contactor, LG heat relay,Carlo Phase;

Protective Device:                    
1.Phase protector
2.Fan overload protector
3.High/low voltage protector
4.Water level protector
5.Anti-freeze protector
Remarks:The cooling capacity of the model is calculated according to condenser temperature 45℃, evaporator temperature  2℃


4.Image of 6ton water cooled process cooling system refrigeration scroll water chiller



5.Company Information
Shen Zhen Anyda Refrigeration Equipment Co., Ltd. is a high-tech private enterprise which was established in 2013,with the registered capital of 5 million yuan, covers an area of 8900 square meters, Anyda gradually grow up step by step.
Anyda is specialized in the research, production and trading of industrial refrigeration technology and facilities. We have gradually produced Industrial Chiller,Water Chiller,Air Cooler,Oil Chiller,Low Temperature Chillers,Hot Water Chiller, HeatPumps and Central Air Conditioner which are widely applied to  plastic & rubber machinery, daily-use chemical, textile, general machinery, laser machinery, LCD and PCB industry, electroplating, equipments of laboratory, food, pharmacy, etc .  
 Now we own almost one hundred staff and about five of them are engineers with 15years of chiller R & D and production management manufacturing experience which provide the best technical support to our customer.
We gained the certification of ISO9001:2008 and CE international quality management systems. We have exported to Russia,Uzbekistan,Kazakhstan,Saudi Arabia,Africa,Indonesia,Malaysia,Romania,Bulgaria,Australia,Palestine,SriLanka,Mexico,Amercia,Lebanon ,Lithuania and so on,which covered about USD2millions.We are looking forward to your suggestion, and are confident of becoming your choice!

6.Delivery, Shipping and Service of 6ton water cooled process cooling system refrigeration scroll water chiller
Payment:
30%TT as the deposit,70% TT balanced before delivery.
Delivery:
Standard Model: 15-20days after receiving the deposit.
Customized Model: 25-35days after receiving the deposit.
Package
Wooden case by bulk-cargo
Simple package by a container
Service:
1. Customized product is welcome.
2.1year guarantee,if any parts broken in this period,we will send you the new one for replacement(not including the international express fee).
3.Strong R&D team,we will supply technical support forever.

7.FAQ
1.Water chiller how it works?
Chiller has two circulation,one is process water circulation,the other is refrigerant
gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.  Heat load calculation for chiller?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.  Types of chiller system
Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.
4.  Chiller capacity unit?
1 kcal/h = 1.163W,1 W = 0.8598 kcal/h;
1 Btu/h = 0.2931W,1 W = 3.412 Btu/h;
1 USRT  = 3.517 kW,1 kW = 0.28434 USRT;  
1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h;
1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT;
5.  Use of chiller?
Plastics
In the plastics industry, a chilling system cools the hot plastic that is injected, blown, extruded or stamped. A chilling system can also cool down the equipment that is used to create plastic products (hydraulics of the molding machine, gear box and barrel of the extruder) that saves on energy and on the wear and tear of the machine itself.
Printing
In the printing industry, a chiller not only removes the heat generated by the friction of the printing rollers, but cools down the paper after it comes out of the ink drying ovens in the process.
Laser
In the laser cutting industry, light projection industry, etc. a chilling system is used to cool down the lasers and power supplies.
Rubber
In the rubber industry to cool the multizone water temperature control units of the rubber extruder barrel, cool the rubber mill, calendars and bambury mixers.
Beverage
In the beverage industry, a chiller removes the heat gained from the process during mixing, cooking, or after pasteurizing the product.
Medical
If you use high tech equipment for magnetic resonance imaging, scanning, blood cooling and laboratory testing, you'll need a cooling system to remove all the heat generated.
Hvac
With cooling expenses accounting for 30% to 50% of your total energy costs and rising fast, and the impending phaseout of chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants, there is a rapidly growing need to replace large commercial air conditioning and refrigeration systems with a modular chilling system.
6.Chiller maintenance?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant


ANYDA is well acknowledged as one of the leading manufacturers of 6ton water cooled process cooling system refrigeration scroll water chiller in China. All of the products for sale are made in our professional plant. Should you're interested in it, please be free to get the high-tech equipment with competitive price from us.

Message

TO: anyida

E-mail:

Content:

Contact information
Comment
0